Operation Modes
151174 4-5
26. Press *. The display shows SYSTEM MESSAGES
ENTER APT #
This selects the display message that the user will see during normal operation.
27. Press any number to toggle through the display message choices. (See Table 4-2 for list of
choices.)
28. Press *. The display shows AUX RELAY
DISABLED
If enabled the aux relay is operational as a secondary tone or rotary controlled relay. If
Alarm is selected the auxiliary will be used as an alarm output. If ground start is selected
the auxiliary relay will be used for phone systems that use ground start phone operations.
If disable the auxiliary relay will not operate. If ring detect is selected the control panel
will activate a sounding device connected to the auxiliary relay, that will notify an
attendant that there is an incoming call to the control panel (see Section 6.5 for operation).
29. Press any number to toggle the display between ENABLE, ALARM, GROUND START,
RING DETECT or DISABLE.
30. Press *. The display shows AUX TIME WINDOW
ENABLED
This option enables or disables the programmed auxiliary time window which is
programmed in operating mode 2 “Time Set”. If Aux Time Window is enabled and Aux
Relay is enabled, then the aux relay will only be enabled during the programmed time
window. If Aux Time Window is disabled and Aux Relay enabled, then the auxiliary can
be used anytime (see Section 6.3 for Auxiliary Door Access Operation). If Aux Relay is
disabled, then Aux Time Window will not function. If the continuous option is chosen
then the auxiliary relay will be energized for the entire aux time window.
31. Press any number to toggle the display between ENABLE, DISABLE and
CONTINUOUS.
32. Press *. The display shows SPEAKER VOLUME
The speaker volume can be set to low, medium, or high.
33. Press any number to toggle to the desired choice.
34. Press *. The display shows ANSWER RINGS
Enter the number of rings before the entry system will automatically pick up to
communicate with the up/down loading computer. Range from 0 to 15.
Note: If 0 is selected for Answer Rings the control panel will never begin communication with up/down loading
software.