Series 5000 Entry System Installation/Operation Manual
3-20 151174
3. Remove the red cap from the mail carrier lock button. (See Figure 3-15 for red cap loca-
tion.)
4. Adjust the push-button switch so that the button is completely out when the mail carrier
key is turned in the lock.
Note: If the mail carrier lock is not used, do not remove the red cap from the mail carrier button.
3.5.13 Installing a Sonalert/Piezo to the Alarm Output
In installation sites requiring an alarm output when the door access codes are tampered with, a
sonalert/piezo (12 VDC, 100 mA maximum) can be installed.
Follow these instructions to install a sonalert to the control panel.
1. Connect a sonalert across terminals 7 and 10. (See Figure 3-16.)
Figure 3-16 Sonalert/Piezo to 5083/5084 Control Panel Wiring Diagram
2. Connect a jumper wire across terminals 6 and 11. (See Figure 3-16.)
3. Set the auxiliary relay to the “ALARM” selection in “System Options” in programming.
(See Section 4.2.1 step 28.)
Note: 5083 and 5084 installations using a secondary touch-tone relay or a ground start telephone system CAN-
NOT use the alarm output.