Programming
150966 6-17
Code Required for
Bypassing
If this option is enabled, users must enter a code to bypass or reinstate
(unbypass) zones even if the system is disarmed. This option applies
only to zones that can be bypassed manually. It does not apply to
unbypassable zones. (Unbypassable zones can be bypassed only
through auto closings, which are initiated by the system, not the user.)
This option must be enabled in a UL listed application.
Disabled
Fast Restore after Alarm If this option is enabled, zone restores are reported to the central
station immediately. If this option is not selected, restores are not
reported to the central station until the end of the audio output
shutdown time or until the zone is reset.
Disabled
Use Interactive Menus When this option is selected, all users will use interactive menus to
operate the system.
If this option is not selected, users in single-area systems can operate
the system by pressing the appropriate key on the Touchpad (toggling
method).
Multi-area systems always use some type of interactive menu, but if
the interactive menu option is not enabled, the operation will be
slightly different. Refer to Section 5 for more information about
system operation.
Disabled
Anti-Passback Enabled When enabled, every user entry access must be followed by an exit
before a second entry is allowed. A user cannot access two entry doors
in a row or two exit doors in a row. When the system is reset or
powered up, the first access for a user can be either exit or entry and
determines what type of access is allowed to follow. Doors specified
as “Inside” doors can only be accessed by those users with “In” status.
Doors specified as “Outside” doors can only be accessed by those
users who have “Out” status.
Disabled
Entry Delay Beeps on
Internal 1 Speaker
If this option is selected, an audible warning tone is sounded at the
internal 1 speaker during entry delays for all areas within this partition.
Disabled
Exit Delay Beeps on Internal
1 Speaker
If this option is selected, an audible warning tone is sounded at the
internal 1 speaker during exit delays for all areas within this partition.
Disabled
Chime Beeps on Internal 1
Speaker
If this option is selected, an audible chime tone sounds at the internal
1 speaker when an active chime zone changes from Ready to Not
Ready (or vice versa). The tones are different to distinguish between
door openings and closings. The chime sound occurs only if the zone
state change occurs with the zone disarmed.
Disabled
Bell after Closing Report
Acknowledged
If this option is selected, whenever a closing report occurs for this par-
tition, two seconds of intrusion alarm tones will sound on the bell out-
put and at all speakers after the report to the central station is
complete. This option must be enabled in a UL Central Station Service
commercial burglary installation.
Disabled
Two Second Bell Test when
Areas Arm
If this option is selected, whenever an area within this partition is
armed (either manually or automatically), two seconds of intrusion
alarm tones will sound at all speakers and the bell output.
Disabled
Table 6-5: Partition Options and Description